HOME / PRODUCTS / LINEAR SCONCES / MINILUX SQ LS01
LINEAR SCONCES
LS01
Minilux SQ
LINEAR SCONCE UP-LIGHT
Minilux SQ = approximately “SQuare” extrusion shape [Consider using our AL03 HRL fixture, when glare might be a concern]
Any length
No transformer or driver necessary
Dimmable
ETL Approved to meet UL Standards
SIZES
Length: almost any length—Please specify in units-of-an-inch [Note: lengths over 12 feet will require a seam]
Protrusion (the distance FROM face-of-wall TO front-of-fixture):
Length: almost any length—Please specify in units-of-an-inch [Note: lengths over 12 feet will require a discrete seam]
Protrusion (the distance FROM face-of-wall TO front-of-fixture):
Standard protrusions are 6”, 10” and 16” stems.
Custom protrusions: are available with an up-charge (with all mountings, except MM02)
LIGHT SOURCES
LED boards (Close to zero UV)
14 Watts 1200 Lumens (per foot diffused optic)
Color Temperature: 2700K -or- 3000K 95 CRI
120 Volts Dimmable ETL Approved
These LED’s operate on line voltage, and NO separate driver or transformer is needed.
LED lamps (Close to zero UV)
6 Watts 75 Watt incandescent equivalent 900 lumens (each lamp)
Color Temperature: 2700K -or- 3000K 80+ CRI
Base: Bayonet, double-contact base, BA15d
120 Volts - Dimmable ETL Approved
Note: Lamps are usually spaced approximately 12” apart
These LED’s operate on line voltage, and NO separate driver or transformer is needed.
JD Krypton lamps (Blocks UV)
20, 40, or 60 Watts (each lamp)
Base: Bayonet, double-contact base, BA15d
120 Volts
Note: Lamps are usually spaced approximately 12” apart
JD Halogen lamps
50 or 75 Watts (each lamp)
Base: Bayonet, double-contact base, BA15d
130 Volts
Note: Lamps are usually spaced approximately 12” apart
NOTE:
Fixtures are provided with a set of lamps (or, if specified or integral to the fixture’s design, with LED’s), as specified by the customer.
It is the customer’s responsibility to verify that their selection is compatible with their wiring, power, switching, and dimming system.
MOUNTING METHODS
MM01A (hardwired, with screws visible)
MM01B (hardwired, with No screws visible) – the most typically specified mounting
MM02 (on wall-mounted arm(s), plugged into outlet)
MM03A (through a millwork fascia, hardwired)
MM03B (through a millwork fascia, plugged in)
MM04A (over or under a fixed shelf, with multiple stems)
MM04B (over or under a fixed shelf, with a single stem)
NOTE: Fixtures will be provided for installation with normal mounting conditions. It is the customer’s responsibility to verify that they have selected a fixture and mounting method which complies with local codes (L.A.H.J.) and that they are installing the fixture in an approved manner.
DRAWINGS AND FILES